Liquid Synthetic Ice

Liquid Synthetic Ice

The foundation under the ice surface requires C25 to harden the ground. It is poured at room  temperature on site to form a whole with the foundation without empty drums and flat surface without joints.
      Liquid synthetic ice is an emerging product of simulated ice. It breaks the embarrassment of the simulated ice plate stitching, thermal expansion and contraction, the inability to embed the marking lines, and the need for special ice skates.

Performance Advantage

The same small molecular structure as the real ice can make the ice skates break and slide. The "ice surface" naturally produces a lubricating factor, making taxiing smoother.

Performance Comparison of Wajufo Synthetic Ice and existing Synthetic Ice in The Market
Performance characteristics Wajufo liquid synthetic ice Synthetic Ice Rink
Material Modified two-component synthetic resin Polyethylene
Production Method Ice pouring on site at room temperature On-site assembly of plastic panels
Whether there are seams One-piece molding without seams Lots of seams
Can the marking line be buried under the ice? Can Can not
Whether professional bladed ice skates? Yes No professional edge
Whether to polish and wax every day? No need Polished and waxed every day
Is there a gap between the ice layer and the foundation No yes
Sensitivity to temperature Not sensitive It expands and shrinks when heated, and shrinks when it cools down
Ice surface changes after taxiing A small amount of ice slag A lot of burrs or plastic filaments
Static electricity situation Very low static A large amount of electrostatic adsorption of dust
Maintenance cost Extremely low Low
Can the ice be repaired at any time Can Can not
Basic requirements Qualified commercial mixed floor Qualified commercial mixed floor
3m ruler≤3mm 3m ruler≤3mm

Comparison of business characteristics of ice rink construction

Feature content

Refrigeration ice rink

Ecological ice rink

Venue space requirements

 

Special venues for ice rinks, with floors above 7 meters, need to be equipped with professional equipment rooms

Conventional indoor space, and outdoor canopy space, no equipment room is required

Venue dehumidification and exhaust requirements

A complete dehumidification and exhaust system needs to be installed in the venue, and a sufficient number of corresponding equipment needs to be configured.

No need to install a dedicated dehumidification system

Basic requirements for ice rink

Special multi-layer complex structure

Ordinary conventional concrete floor above C25

 

Matching equipment for site use

Need to configure large refrigeration units, cooling equipment, dehumidification and exhaust equipment

No need to configure equipment

Maintenance equipment

Need to configure professional ice sweeping and pouring equipment

Configure simple mop, suction device and curing agent

Professional staffing requirements

Need professional equipment maintenance personnel, need professional ice maker

Configure general sanitary cleaners

(1800 square meters standard ice hockey rink)

Water and electricity costs 1.8-3.0 million/year (different construction areas and equipment used have different energy consumption. Site lighting and air-conditioning are not included)

Water and electricity fee for ice rink: 0

(Excluding venue lighting and air conditioning)

Maintenance cost

(Equipment maintenance and technical personnel)

 

Technical personnel and equipment accessories: 500,000-800,000/year

Labor and materials: 50,000-80,000/year

Routine maintenance intervals

Many times a day, pouring ice for maintenance

Sanitation cleaning: 1 time/day

Site maintenance: 1 time/week

Venue life

6-10 year

5-8year

Comparison of technical characteristics of ice rink use

Feature content

Artificial refrigeration ice rink

Ecological ice rink

Ice making material

Water + electricity

Modified polymer

Ice making method

 

Professional water refrigeration system makes ice,

Keep water and electricity frozen

Pouring on-site and making "ice" at room temperature

One-time molding, long-term use

Are there seams on the ice

Seamless

Seamless

Whether the ice layer and foundation are hollow

Blended into one, no hollow drum

Blended into one, no hollow drum

Whether the marking can be embedded on the ice surface

Can pre-embed marking slogans, logos, etc.

Can pre-embed marking slogans, logos, etc.

Whether to use professional ice skates

 

Use regular professional bladed ice skates

Use regular professional bladed ice skates

Whether to produce self-lubricating

Ice water mixture lubrication factor

The ice rink can continuously penetrate the self-lubricating factor

Sliding lubricity

Excellent

Close to water cooling ice 80-90%

 

Ice surface loss

 

Great, every time you rub and brake, the ice surface will cause greater damage

Very small, every time you rub ice and brake, small ice powder will be produced on the ice surface, and the loss is small.

 

Can the ice be repaired

Sweep the ice to repair the ice surface every day

Friction to a certain degree (2-3 years), sand the area with greater wear, and re-spray the ice surface

The site is suitable for the ambient temperature

Stay below zero

Suitable for -45℃-50℃ floor temperature

Do Real Ice Action

The standard sliding push pot action consistent with the real ice, and the ice sliding and quick stop.    Switch to real ice field training and zero obstacles in competition.